Control (DC_STS) Shorted Wire Inspection
NOTE:
Before disconnecting the PCM connector, jump the SCS line with the HDS, and wait more than 1 minute.
Test Procedure
- Preparation
- DC-DC converter connector A (3P) : disconnected
- PCM connector A (50P) : disconnected
- Procedure
- Perform the inspection according to the following table.NOTE: Refer to the Open/Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.
(Disconnected)
DC-DC converter connector A (3P) female terminalsIG Mode Normal Conditions DC_STS shorted to ground inspection OFF Not shorted - Perform the inspection according to the following table.
Results
- If abnormal, there is a problem in the circuit.