A/C Pressure Sensor Inspection
NOTE:
Since there is no direct method to test the component itself, troubleshooting is performed on the related components.
Test Procedure
PCM output voltage inspection
- Preparation
- A/C pressure sensor 3P connector: disconnected
- Procedure
- Jump A/C pressure sensor 3P connector terminals No. 1 and No. 2 with a jumper wire.
- Turn the vehicle to the ON mode.
- Confirm the HDS [ A/C Pressure Sensor Voltage ].
(Disconnected)
A/C pressure sensor 3P connector female terminals
- Normal Conditions
- HDS [ A/C Pressure Sensor Voltage ] value is less than 4.75 V .
Results
- If it is normal, there is a problem with the A/C pressure sensor.
- If it is abnormal, there is a problem with the related components.