A/F Sensor (Sensor 1) Inspection
Preconditions
- At room temperature
Test Procedure
- Preparation
- A/F sensor (Sensor 1) connector 6P : disconnected
- Procedure
- Perform the inspection according to the following table.
(Disconnected)
A/F sensor (Sensor 1) connector 6P male terminalsIG Mode Normal Conditions Sensor internal circuit inspection OFF About 2.8 - 4.5 Ω OFF*1 Not shorted OFF*1 Not shorted OFF*1 Not shorted OFF*1 Not shorted OFF*1 Not shorted OFF There is no continuity OFF There is no continuity OFF There is no continuity *1: A/F sensor (Sensor 1) is installed
- Perform the inspection according to the following table.
Results
- If it is abnormal, there is a problem in the A/F sensor (Sensor 1).