Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Acura >> 2000 >> Integra GS-R, 4D Sedan >> Repair and Diagnosis >> Engine Performance >> Mode 6 - 2000 ACURA >> SAE J1979 Mode $06 Information by Test ID >> PHO2S Heater (Bank 2)

PHO2S Heater (Bank 2)

DTC P0155: Test ID $12: Component ID $81

Test ID $12 Test Limit Type and Component ID $81
DTC P0155
Test Description Circuit check of A/F sensor heater by monitoring the sensor output current during heater on.
Store Timing Normal judgement/Failure judgement
Conversion to Engineering Units Measured value: Output value (Decimal) x 7.86 (mA)
The lowest limit value: Output value (Decimal) x 7.86 (mA)
The highest limit value: Not applicable
DTC P0155: Test ID $13: Component ID $01

Test ID $13 Test Limit Type and Component ID $01
DTC P0155
Test Description Circuit check of A/F sensor heater by monitoring the sensor output current during heater on.
Store Timing Normal judgement/Failure judgement
Conversion to Engineering Units Measured value: Output value (Decimal) x 7.86 (mA)
The lowest limit value: Not applicable
The highest limit value: Output value (Decimal) x 7.86 (mA)
DTC P0155: Test ID $12: Component ID $85

Test ID $12 Test Limit Type and Component ID $85
DTC P0155
Test Description Circuit check of A/F sensor heater by monitoring the sensor output current during heater on.
Store Timing Normal judgement/Failure judgement
Conversion to Engineering Units Measured value: Output value x 26.7 (mA)
The lowest limit value: Output value x 26.7 (mA)
The highest limit value: Not applicable
DTC P0155: Test ID $13: Component ID $05

Test ID $13 Test Limit Type and Component ID $05
DTC P0155
Test Description Circuit check of A/F sensor heater by monitoring the sensor output current during heater on.
Store Timing Normal judgement/Failure judgement
Conversion to Engineering Units Measured value: Output value x 26.7 (mA)
The lowest limit value: Not applicable
The highest limit value: Output value x 26.7 (mA)