Mike's Workshop Manuals: Service manuals for every vehicle
Home >> Acura >> 1998 >> Integra GS-R, 2D Coupe >> Repair and Diagnosis >> External Pages >> Different car >> Section 27 (A/C-Heater System) >> Self-Diagnostics >> Code B: Outside Air Temperature Sensor

Code B: Outside Air Temperature Sensor

WARNING: This page is about a different car, the 1998 Acura 3.5RL. However, it is still accessible from the selected car via links, so may be relevant.
CAUTION: To avoid damage to sensor, use an ohmmeter with a measuring current of one milliamp or less.
  1. Remove outside air temperature sensor. See procedures in OUTSIDE AIR TEMPERATURE SENSOR R & I  . Measure resistance across sensor terminals. See OUTSIDE AIR TEMPERATURE SENSOR RESISTANCE  table under TESTING. If resistance is not as specified, replace sensor.
  2. If resistance is within specifications, remove climate control unit and disconnect 8-pin and 20-pin connectors. Measure resistance between ground and terminal No. 5 (Brown/White wire) of climate control unit 20-pin connector. See Figure . If resistance is less than 10 ohms, repair short in wire between climate control unit, outside air temperature sensor, and gauge assembly, or check gauge assembly.
  3. If resistance is greater than 10 ohms, check for continuity between terminal No. 5 (Brown/White wire) of climate control unit 20-pin connector and outside air temperature sensor. If continuity does not exist, repair open Brown/White wire between climate control unit and outside air temperature sensor.
  4. If continuity does exist, check for continuity in Pink/Blue wire between climate control unit 8-pin connector and outside air temperature sensor. If continuity does not exist, repair open Pink/Blue wire between climate control unit and outside air temperature sensor.
  5. If continuity does exist, check for loose wires or poor connections at climate control unit 8-pin and 20-pin connectors and outside air temperature sensor connector. If connections are okay, substitute known-good climate control unit and recheck. If symptom does not exist after substituting known-good climate control unit, replace original climate control unit.